2024 SR Katalógus - Flipbook - Page 26
FLARE NUT (FN)
17d16= Common Centerline / 36.5 mm Common Centerline
B
D
F
A
E
Part No.
Model
Size (in.)
A (in.)
B (in.)
C (in.)
D (in.)
E (in.)
F (in.)
Max
Torque
(in. lbs.)
819025
FN-1/4
1/4
1.75
0.625
0.3438
0.75
0.6875
0.1875
100
819026
FN-5/16
5/16
1.8125
0.625
0.3594
0.75
0.6875
0.1875
150
819027
FN-3/8
3/8
1.8594
0.8438
0.375
0.75
0.6875
0.2813
200
819028
FN-7/16
7/16
1.8594
0.8438
0.375
0.75
0.6875
0.3438
250
819029
FN-1/2
1/2
1.9688
1.0625
0.4063
0.875
0.6875
0.375
300
819030
FN-9/16
9/16
1.9688
1.0625
0.4688
1.0
0.8125
0.4375
350
819031
FN-5d8
819032
FN-11/16
819033
FN-3/4
5/8
2.0
1.125
0.5313
1.0
0.8125
0.5313
400
11/16
2.0625
1.3125
0.54688
1.0
0.8125
0.5313
475
3/4
2.0625
1.3125
0.54688
1.0
0.8125
0.5313
600
C
"
"
"
"
819034
FN-13/16
819035
FN-7/8
819036
FN-15/16
819037
FN-1
819038
FN-1 1/16
13/16
2.25
1.00
0.625
1.25
0.8125
0.625
700
7/8
2.25
1.50
0.65625
1.25
0.8125
0.6875
800
15/16
2.375
1.5625
0.7188
1.25
0.8125
0.7188
900
1
2.5
1.5625
0.7188
1.25
0.8125
0.75
1000
1 1/16
2.5
1.5625
0.875
1.25
0.8125
0.75
1050
Part No.
Model
Size (mm)
A (mm)
B (mm)
C (mm)
D (mm)
E (mm)
F (mm)
Max
Torque
(Nm)
809243
FN-8 mm
8
45.72
20.32
10.16
20.32
20.32
7.62
16
809217
FN-9 mm
9
45.72
20.32
10.16
20.32
20.32
7.62
19
809218
FN-10 mm
10
45.72
20.32
10.16
20.32
20.32
7.62
22
809221
FN-11 mm
11
45.72
20.32
10.16
20.32
20.32
7.62
28
809241
FN-12 mm
12
48.26
25.40
10.16
22.86
20.32
10.16
30
809219
FN-13 mm
13
48.26
25.40
10.16
22.86
20.32
10.16
33
809220
FN-14 mm
14
50.80
27.94
12.70
25.40
20.32
10.16
40
809222
FN-15 mm
15
50.80
27.94
12.70
25.40
20.32
10.16
45
809238
FN-16 mm
16
50.80
27.94
12.70
25.40
20.32
12.70
50
809223
FN-17 mm
17
53.34
33.02
15.24
25.40
20.32
12.70
54
809239
FN-18 mm
18
53.34
33.02
15.24
25.40
20.32
15.24
61
809224
FN-19 mm
19
53.34
33.02
15.25
25.40
20.32
15.24
68
809240
FN-21 mm
21
53.34
38.10
17.78
33.02
20.32
17.78
80
809242
FN-22 mm
22
55.88
38.10
17.78
33.02
20.32
17.78
90
809225
FN-24 mm
24
55.88
40.64
17.78
33.02
20.32
17.78
105
Do not exceed rated torque
Do not use to break fasteners loose
Periodic recalibration is necessary to
maintain accuracy
Read safety precautions on page 59