20240202 EYF General Catalogue Final English KOPEX - Flipbook - Page 8
Shut-Off Tool Functions/Features Overview
Stuffed with variety of reliability and user-friendly technologies
Low Noise Shut-Off Series
Low Noise
Shut-Off
Mechanical
Pulse
Clutch Screwdriver Cordless Series
Shut-Off Series
Shut-Off Mechanical Pulse
High Spec
Shut-Off
Shut-Off
Shut-Off
High Torque /
Right Angle
EYFLA7, 8, 9
EYFLA4, 5, 6
EYFNA1, PA1
EYFMA2
EYFMA1
EYFME1
EYFLF1, 2
Functions
Improved Soft Joint Performance
Torque
Target Torque
Auto Shut-off
Torque Calculation Mode
Target
torque
7-Stage Flush Point Detection
Mode for varying joint types
Flush Point Detection Mode setting
L7
•
√
√
√
√
√
OK/NOK LED, Buzzer
√
√
√
√
√
Battery Level LED
√
√
√
√
√
√
(360°)
√
(360°)
Soft Start
Lower the no load starting speed for a
programmable time.
Reverse Start
(reversing angle)
Starting reverse rotation for thread
alignment before forward rotation.
√
(180°/360°)
√
(360°)
Variable Speed On / Off
Enables to select variable speed or
single speed trigger operation.
√
√
√
√
√
√
√
√
√
√
√
(7)
√
(7)
√
(2)
√
(2)
L5
L4 Flush Point Detection Mode
L3
Calculation of applied torque
towards snug point
If the tool does not reach snug
torque and stops before snug
point select a L setting (L3~L7)
L2
Remote Mode Setting
L1
Time
Snug Torque Detection
Rundown
Flush
Enables accurate fastening by selecting
昀氀ush point detection level.
Delays 昀氀ush torque detection activation by
ignoring loads for a selected time period.
√
√
Cross Thread Prevention
Alerts NOK if the shut-off is activated
before the preset minimum runtime.
√
√
Flush Point: The point where the head of
the fastener meets the material. Finger tight.
L1: Brittle plastic or hard joint, no prevailing torque.
Parts are snug.
Snug Point: The point where materials
are pulled together completely and torque
calculation mode begins.
L2: Minor prevailing torque. Parts need to be pulled
together.
Re-tightening Prevention
Prevents double tightening within a
selected time period after shut-off.
√
√
L3-L7: Major pulling of parts together before snug.
Obvious gaps in layers of material.
Socket Extention Mode
(h1: 150mm, h2 250mm socket)
Chose suitable speed for stable pulse
according socket length.
√
√
Maintenance Interval Alarm
Notify preset maintenance interval by
blinking LED when the remaining is:
√
√
2-way Communication
(radio/wireless type only)
Control tool settings both via remote or
EYFR03B controller.
√
√
Out of Range Disable
(radio/wireless type only)
Disable tool operation if the wireless
communication cannot be completed.
(√)
(√)
Stable Pulse Power Control
Keep power of each pulse consistent
regardless of remaining battery capacity.
√
√
1
Setting
torque
Stable Pulse Power Control /
Pulse Ampli昀椀cation
2
Auto Power Shut Down
Before battery power becomes too
low to maintain torque, tool shuts
down automatically.
The preset shut-off torque is kept consistent
regardless of remaining battery capacity,
minimizing variation in torque.
Torque
▶ Pulse Ampli昀椀cation
Consistent torque
Tool without
Consistent
Torque Control
100~40%
Battery
indication
lamp
13
√
Flush Detection Delay
Snug
Consistent Torque Control
Auto Battery
shut down
indication
40~20%
Less than 20%
Time to
charge
reminder
Auto battery
shut down
indication
√
√
√
√
(1 hour operation)
Amplify pulse frequency when the rotation
is decreased due to lower battery voltage.
Shuts down tool automatically before the
battery power becomes too low.
√
√
√
(10,000 fastenings)
(√)
(√)
√
√
√
√
√
√
√
Color Plate by Torque Range
(with serial #)
√
√
√
√
√
Tool Hanger
√
√
√
√
Auto Power Shut Down
Battery
Capacity
√
Features
▶ (stage)
Time
EYFGA
EYFEA1
1, 2, 3
LED Work Light
Snug Point
L1 : For light loads application
L2-L7 : For heavy loads application
Cordless
Clutch
Screwdriver
√
√
14